Export 21 results:

Journal Article

Conference Paper

  1. [FINE-97f]G. Finet, Cachard, C., and Maurincomme, E., Intravascular ultrasound artifacts after stent implantation, in World Congress on Medical Physics and Biomedical Engineering, Nice, France, 1997, vol. 35, p. part I-401.
  2. [FINE-97e]G. Finet, Cachard, C., Maurincomme, E., Rioufol, G., Abrysch, F., and Beaune, J., Impact of intravascular ultrasound image artifacts on stent quantitative measurements, in XIXth Congress of the European Society of Cardiology, Stockholm, Sweden, 1997, vol. 18, p. 380.
  3. [FINE-97c]G. Finet, Cachard, C., Maurincomme, E., Rioufol, G., Abrysch, F., and Beaune, J., Artifacts in intravascular ultrasound imaging during coronary artery stent implantation, in XXIth Congress of the European Society of Cardiology, Stockholm, Sweden, 1997, vol. 18, p. 133.
  4. [MAUR-95]E. Maurincomme, Finet, G., Reiber, J. H. C., Savalle, L., and Magnin, I. E., Quantitative intravascular ultrasound imaging : evaluation of an automatic approach, in 44nd Annual Scientific Session of American College of Cardiology, California, USA, 1995, p. 354A.
  5. [FINE-95c]G. Finet, Maurincomme, E., Reiber, J. H. C., Savalle, L., and Beaune, J., Quantification par échographie endovasculaire : évaluation d'une approche automatique, in VIe Journées Européennes de la Société Française de Cardiologie - 16 Décembre, Paris, France, 1995, vol. 89, p. 112.
  6. [MAUR-93]E. Maurincomme, Friboulet, D., Finet, G., Magnin, I. E., and Reiber, J. H. C., ADDER : A snake-based segmentation approach for intravascular ultrasound images, in 2nd Int. Conf. Digit. Image Computing : techniques and applications, Sydney, Australia, 1993, pp. 422–429.
  7. [PEYR-92f]F. Peyrin, Houssard, J. P., Maurincomme, E., Peix, G., Goutte, R., Laval-Jeantet, A. M., and Amiel, M., 3D display of high resolution vertebral structure images, in IEEE EMBS Satellite Symposium on 3D Advanced Image Processing in medicine, Rennes, France, 1992, pp. 15–19.
  8. [MAUR-92]E. Maurincomme, Magnin, I. E., Finet, G., and Goutte, R., Methodology for three-dimensional reconstruction of intravascular ultrasound images, in Int. Conf. SPIE Medical Imaging VI : Image capture, formatting and display, Newport Beach, USA, 1992, vol. 1653, pp. 26–34.
  9. [FINE-92b]G. Finet, Tabib, A., Maurincomme, E., Roriz, R., Douek, P., Magnin, I. E., Beaune, J., and Amiel, M., Artefacts in intravascular ultrasound imaging : an in vitro study, in CIRSE'92 : Cardiovascular and Interventional Radiology Society of Europe, Barcelona, Spain, 1992, vol. 15, p. S12.

Thesis

  1. [MAUR-94]E. Maurincomme, Analyse et segmentation d'images échographique endovasculaires, INSA Lyon, 1994.
    Amiel M., Eebel R. (rap.), Goutte R. (prés.), Preteux F. (rap.), Friboulet D., Magnin I.E. (dir.), Morvan J.M. et Reiber J.H.C. (rap.)