BACK TO INDEX

Publications of year 2007
Books
  1. [GIRA-07] P. R. Girard. Quaternions, Clifford Algebras and Relativistic Physics. 2007.


  2. [TAYL-07] Ian Taylor, Ewa Deelman, Dennis Gannon, and Matthew Shields. Workflows for e-Science. Springer-Verlag, 2007.


Book chapters
  1. [BASS-07] O. Basset and C. Cachard. Ultrasound Image Post-Processing: application to segmentation. In Physics for Medical Imaging Application, pages 227-239. Y. Lemoigne, A. Caner, and G. Rahal, editors. Springer - NATO Science Series, Publ., Dordrecht, The Netherlands, 2007.


  2. [CACH-07] C. Cachard and O. Basset. Ultrasound Contrast Agents. In Physics for Medical Imaging Application, pages 137-150. Y. Lemoigne, A. Caner, and G. Rahal, editors. Springer Verlag - NATO Science Series, Dordrecht, The Netherlands, 2007.


  3. [GLAT-07] Tristan Glatard, Gergely Sipos, Johan Montagnat, Zoltan Farkas, and Peter Kacsuk. Workflow Level Parametric Study Support by MOTEUR and the P-GRADE Portal. In Workflows for e-Science, chapter 18, pages 279-299. I.J. Taylor, E. Deelman, D. Gannon, and M. Shields, editors. Springer, 2007.


  4. [GUER-07f] C. Guérin, A. Koutsoukou, J. Milic-Emili, and E. D'Angelo. Lung mechanics in COPD, cystic fibrosis, restrictive chest disease and interstitial lung fibrosis. In Mechanical Ventilation: clinical Applications and Pathophysiology, Section two. Physiology and pathophysiology of ventilation. B- Ventilation mechanics, pages 100-110. R. Robert, P. Honoré, and O. Bastien, editors. Elsevier, Publ., Some City, Some Country, 2007.


  5. [HASS-07] M. Hasselmann, M. Boncompain-Gérard, and C. Guérin. Pharmaconutriments lipidiques. In Traité de nutrition artificielle de l'adulte. 3ème Edition, pages 733-734. N. Cano, D. Barnoud, S. Schnieder, M.P. Vasson, M. Hasselmann, and X. Leverve, editors. Springer Verlag, Some City, Some Country, 2007.


  6. [LAC-07] J.O. Lachaud and S. Valette. Chap. 12 : Approximation par triangulation. In Géométrie discrète et images numériques, Traité IC2, Signal et Image, pages 265-282. D. Coeurjolly, A. Montanvert, and J.M. Chassery, editors. Hermès, Publ., Paris, France, September 2007.


  7. [MAMO-07] K. Mamou, F. Prêteux, R. Prost, and S. Valette. Chap. 9 : Compression des maillages surfaciques 3D statiques et dynamiques. In Compression des images et des signaux médicaux, Traité IC2 Information et sciences du vivant, pages 231-268. A. Naït-Ali and C. Cavaro-Ménard, editors. Hermès, Publ., Paris, France, 2007.


Thesis
  1. [BARV-07] M.. Barva. Localization of Surgical Instruments in 3D Ultrasound Images. Doctorat, Université Lyon 1, Czech Technical University in Prague, 2007. Jury: Cachard, C., Hlavac V., Kybic J, Haigron P., Pollak P., Sequeira J., Berka P., Lapon C., Vavrin P.


  2. [BOUS-07] L. Boussel. Apport de l'IRM haute résolution à l'imagerie de la paroi carotidienne normale et pathologique.. Doctorat, Université Claude-Bernard Lyon I, 25 Octobre 2007. Jury: Norbert NIGHOGHOSSIAN Président, Emmanuelle CANET-SOULAS, Patrick COZZONE Rapporteur, Philippe DOUEK, Jean-Pierre PRUVO, Didier LETOURNEUR.


  3. [CHO-07] J.W. Cho. Watermarking, Compression, and their Combination for 3-D Triangular Meshes. Doctorat, INSA Lyon, Yeungnam University, 2007. Jury: M. Antonini (rap.), K.R. Kwon (rap.), K.Y. Yoo, I.E. Magnin (prés.), H. S. Kang, F. Preiteux, K. Y. Yoo, H.Y. Jung (dir.), R. Prost (dir.).


  4. [FALC-07b] J. Falconet. Apport de la lumière polarisée linéairement pour la caractérisation optique de milieux diffusants. Doctorat, Université Claude-Bernard Lyon I, 2007. Jury: Basset O. (Prés.), De Martino A. (Rap.), Derouard J. (Rap.), Dinten J.M., Perrin E. (dir.), Sablong R. (co-dir.), Saint-Jalmes H.


  5. [GLAT-2007c] Tristan Glatard. Description, deployment and optimization of medical image analysis workflows on production grids. Doctorat, Université de Nice Sophia-Antipolis, Sophia-Antipolis, November 2007.


  6. [HADD-07b] R. Haddad. Un Modèle numérique anthropomorphique et dynamique du thorax respirant et du coeur battant. Doctorat, INSA Lyon, March 2007. Jury: I. Magnin (Pdt.), M. Garreau (Rap.), B. Perroche (Rap.), R. Fenici, P. Croisille, P. Clarysse (Dir.).


  7. [KIM-07] M.S. Kim. Wavelet transform based digital watermarking for 3-D surface meshes and mesh sequences. Doctorat, INSA Lyon, Yeungnam University, 2007. Jury: F. Schmitt (rap.), K.R. Kwon (rap.), K.Y. Yoo, I.E. Magnin (prés.), H.Y. Jung (dir.), R. Prost (dir.).


  8. [VALT-07] S. Valton. Reconstruction tomographique 3D en géométrie conique à trajectoire circulaire pour un prototype d'imageur bimodal pour le petit animal. Doctorat, INSA Lyon, 2007. Jury: Y. Bizais (rap.), R. Clackdoyle (rap.), R. Lecomte, C. Morel, R. Prost, F. Peyrin(dir.), D. Sappey-Marinier (co-dir).


  9. [VELU-07b] J. Velut. Segmentation par modèle déformable surfacique localement réularisé par spline lissante. Doctorat, INSA Lyon, 2007. Jury: J.-O. Lachaud (rap.), J. Montagnat (rap.),O. Coulon(prés.), H. B. Cattin,C.Odet(dir.),.


Articles in journal
  1. [ALLO-07] A.R. Allouche, M. Aubert-Frécon, and D. Graveron-Demilly. Quantum chemistry-based NMR spin Hamiltonian parameters of GABA for quantitation in magnetic resonance spectroscopy.. Phys Chem Chem Phys, 9(24):3098-3103, 2007.


  2. [ALSA-07g] H. Alsaid, M. Sabbah, Z. Bendahmane, O. Fokapu, J. Felblinger, C. Desbleds-Mansard, C. Corot, A. Briguet, Y. Crémillieux, and E. Canet-Soulas. High-Resolution MRI with real time digital Cardiac and Respiratory Gating in Mice. Nuclear Magnetic Resonance in Biomedicine, 58(6):1157-1163, 2007.


  3. [ALSA-07] H. Alsaid, M. Sabbah, Z. Bendahmane, O. Fokapu, C. Mansard, A. Briguet, Y. Crémillieux, and E. Canet-Soulas. High-resolution contrast-enhancement MRI of atherosclerosis with digital cardiac and respiratory gating in mice. Magn Reson Med, 58(8):(1157-1163), 2007.


  4. [APOS-07] L. Apostol and F. Peyrin. Connectivity Analysis in Very Large 3D Microtomographic Images. IEEE Trans Nucl Sci, 54(1):(197-172), 2007.


  5. [ARME-07] C. Armenean, O. Beuf, M. Armenean, F. Pilleul, E. Perrin, and H. Saint-Jalmes. Interventional MRI : risk of burns to the patient and radiologist. J Radiol, 88(4):599-600, April 2007.


  6. [ATTI-07a] C. Attia, J. Villard, L. Boussel, F. Farhat, J. Robin, D. Revel, and P. Douek. Endovascular repair of localized pathological lesions of the descending thoracic aorta : midterm results. Cardiovasc Intervent Radiol, 30:628-637, 2007.


  7. [BABO-07] L. Baboi, L. Milot, C. Lartizien, C. Roche, J.Y. Scoazec, F. Pilleul, and O. Beuf. Synchronization strategies in T2-weighted MR imaging for detection of liver lesions: Application on a nude mouse model. Biomed Imaging Interv J, 3(4):1-9, 2007.


  8. [BAGO-07] Matthieu Bagory, Françoise Durand-Dubief, Danielle Ibarrola, Christian Confavreux, and Dominique Sappey-Marinier. ''Absolute'' quantification in magnetic resonance spectroscopy: validation of a clinical protocol in multiple sclerosis. Conf Proc IEEE Eng Med Biol Soc, 2007:3458-61, 2007.


  9. [BALO-07] S. Balocco, O. Basset, G. Courbebaisse, E. Boni, P. Tortoli, and C. Cachard. Noninvasive Young modulus evaluation of tissues surrounding pulsatile vessels using ultrasound Doppler measurement. IEEE Trans Ultrason Ferroelectr Freq Control, 54(6):1265-1271, June 2007.


  10. [BAXA-07b] N. Baxan, A. Rengle, J.F. Châteaux, A. Briguet, G. Pasquet, P. Morin, and L. Fakri-Bouchet. Investigation of NMR limits of detection for implantable microcoil. Procs. IEEE Engineering in Medicine and Biology Society, 2007:(4194-7), 2007.


  11. [BERN-07] O. Bernard, B. Touil, J. D'hooge, and D. Friboulet. Statistical modeling of the radio-frequency signal for partially and fully developed speckle based on a Generalized Gaussian model with application to echocardiography. IEEE Trans Ultrason Ferroelectr Freq Control, 54(10):2189-2194, 2007.


  12. [BILL-07a] C. Billet and R. Sablong. Differential optical spectroscopy for absorption characterization of scattering media. Opt Lett, 32(22):3251-3253, November 2007.


  13. [BOLB-07] R. Bolbos, H. Benoit-Cattin, J.B. Langlois, A. Chomel, E. Chereul, C. Odet, P. Pastoureau, M. Janier, and O. Beuf. Knee cartilage thickness measurements using MRI: a 4 1/2-month longitudinal study in the meniscectomized guinea pig model of OA. Osteoarthritis Cartilage, 15(6):656-665, June 2007.


  14. [BOSS-07] E. Bossy, P. Laugier, F. Peyrin, and F. Padilla. Attenuation in trabecular bone: A comparison between numerical simulation and experimental results in human femur. J Acoust Soc Am, 122(4):2469-2475, 2007.


  15. [BOUSS-07b] L. Boussel, P. Douek, and N. Nighoghossian. High resolution MRI of isolated intraluminal clot of the common carotid artery. Neurology, 68(10):788, 2007.


  16. [BOUS-07a] L. Boussel, A. Serusclat, M. Skilton, F. Vincent, S. Bernard, P. Moulin, D. Saloner, and P. Douek. The reliability of high resolution MRI in the measurement of early stage carotid wall thickening. Cardiovasc Magn Reson, 9:771-776, 2007.


  17. [BRUS-07b] E. Brusseau, J.F. Deprez, F. Duboeuf, and O. Basset. Imagerie de la déformation des tissus biologiques par élastographie main-libre. J Radiol, 88:1823-31, 2007.


  18. [BURG-07] A. Burghardt, Y. Wang, H. Elalieh, X. Thibault, D. Bikle, F. Peyrin, and S. Majumdar. Evaluation of foetal bone structure and mineralization in IGF-I deficient mice using synchrotron radiation microtomography and Fourier transform infrared spectroscopy. Bone, 40(1):160-168, 2007.


  19. [CANC-07] R. Cancedda, A. Cedola, A. Guilani, V. Komlev, S. Lagomarsino, M. Mastrogiacomo, F. Peyrin, and F. Rustichelli. Bulk and interface investigations of scaffolds and tissue-engineered bones by X-ray microtomography and X-ray microdiffraction. Biomaterials, 28(15):2505-2524, 2007.


  20. [CANE-08b] E. Canet-Soulas and D. Letourneur. Biomarkers of atherosclerosis and the potential of MRI for the diagnosis of vulnerable plaque. Magn Reson Mater Phy Biol Med, 20:129-142, 2007.


  21. [CANT-07c] D. Cantor Rivera, M. Orkisz, J.A. Arias, L.F. Uriza, and M. Hernández Hoyos. Modelamiento en 3D de patologìas vasculares a partir de imágenes de resonancia magnética sustraìdas. Revista Colombiana de Radiologìa, 18(4):2225-2232, 2007.


  22. [CARR-07] J.F. Carrillo, M. Hernández Hoyos, E.E. Davila-Serrano, and M. Orkisz. Recursive tracking of vascular tree axes in 3D medical images. Int J Comput Assisted Radiol Surg, 1(6):331-339, 2007.


  23. [CHAR-07] M. Charlot, J.B. Pialat, N. Obadia, A. Boibieux, N. Streichenberger, D. Meyronnet, and F. Cotton. Diffusion-weighted imaging in brain aspergillosis. Eur J Neurol, 14(8):912-916, 2007.


  24. [CANE-07d] F. Chaubet, I. Bertholon, J.M. Serfaty, R. Bazeli, H. Alsaid, M. Jandrot-Perrus, C. Zahir, P. Even, L. Bachelet, Z. Touat, E. Lancelot, C. Corot, and E. Canet-Soulas. A new macromolecular paramagnetic MR contrast agent binds to activated human platelets. Contrast Media Mol Imaging, 2:178-188, 2007.


  25. [CHO-07a] T.H. Cho, N. Nighoghossian, M. Wiart, V. Desestret, S. Cakmak, Y. Berthezène, L. Derex, G. Louis-Tisserand, P. Trouillas, J. Honnorat, J.C. Froment, and M. Hermier. USPIO-enhanced MRI of neuroinflammation at the sub-acute stage of ischemic stroke, preliminary data. Cerebrovasc Dis, 24(6):544-546, 2007.


  26. [CHO-07c] J.W. Cho, R. Prost, and H.Y. Jung. An Oblivious Watermarking for 3D Polygonal Meshes Using Distribution of Vertex Norms. IEEE Trans Signal Proc, 55(1):142-155, 2007.


  27. [CIES-07e] K. Cieslar, H. Alsaid, V. Stupar, S. Gaillard, E. Canet-Soulas, R. Fissoune, and Y. Crémillieux. Nonlinear pO(2) decay in mouse lungs using He-3-MRI. Measurement of Nuclear Magnetic Resonance in Biomedicine, 57:383-391, 2007.


  28. [CIES-07c] K. Cieslar, V. Stupar, E. Canet-Soulas, S. Gaillard, and Y. Crémillieux. Alveolar oxygen partial pressure and O2 depletion rate mapping in rats using 3He ventilation imaging. Magn Reson Med, 57:423-430, 2007.


  29. [COTT_07a] F.J. Cotton and G M. Morrison. Artificial ligaments at the knee: a technique. 1934. Clin Orthop Relat Res, 454:15-16; discussion 14, 2007.


  30. [CROI-07a] P. Croisille, C. Rotaru, M. Janier, and B. Hiba. Gender and strain variations in left ventricular cardiac function and mass determined with MRI at 7 Tesla in adult mice. Invest Radiol, 42(1):1-7, January 2007.


  31. [DELP-07a] P. Delpierre, S. Basolo, J.F. Berar, A. Bonissent, P. Breugnon, N. Boudet, B. Caillot, B. Chantepie, J.C. Clemens, F. Debarbieux, B. Dinkespiler, R. Khouri, I. Koudobine, V. Mararazzo, C. Meessen, M. Menouni, C. Morel, C. Mouget, P. Pangaud, F. Peyrin, G. Rougon, D. Sappey-Marinier, S. Valton, and E. Vigeolas. PIXSCAN: Pixel Detector CT-Scanner for Small Animal Imaging. Nucl Instr Meth Phys Res A, 571:425-428, 2007.


  32. [DESB-07] A. Desbrée, L. Rbah, J.B. Langlois, D. Grenier, R. Mastrippolito, F. Pain, L. Pinot, P. Lanièce, L. Zimmer, and H. Gurden. Simultaneous in vivo Magnetic Resonance Imaging and Radioactive Measurements by the B-MicroProbe. Eur J Nucl Med Mol Imaging, 34(11):1868-72, November 2007.


  33. [DOUE-07d] P. Douek. MRI for the Assessment of Organ Vascularization: Impact on Diagnosis and Patient Management. Eur Radiol, 26(10):1412-1423, 2007.


  34. [DUMO-07] J. Dumortier, F. Pilleul, M. Adham, V. Vochelle, V. Hervieu, Y. Bouffard, P.J. Valette, J.Y. Scoazec, and O. Boillot. Severe portal hypertension secondary to arterio-portal fistula: salvage surgical treatment. Liver Int, 27(6):865-868, August 2007.


  35. [FARH-07a] F. Farhat, C. Attia, L. Boussel, P. Staat, D. Revel, P. Douek, and J. Villard. Endovascular repair of the descending thoracic aorta: mid-term results and evaluation of magnetic resonance angiography. J Cardiovasc Surg, 48(1):1-6, 2007.


  36. [FARH-07] F. Farhat, M. Durand, L. Boussel, I. Sanchez, J. Villard, and O. Jegaden. Should a reimplantation valve sparing procedure be done systematically in type A aortic dissection?. Eur J Cardiothorac Surg, 31(1):36-41, 2007.


  37. [FINE-07] G. Finet, M. Gilard, B. Perrenot, G. Rioufol, P. Motreff, L. Gavit, and R. Prost. Fractal geometry of arterial coronary bifurcations. A quantitative coronary angiography and intravascular ultrasound analysis. EuroIntervention, 3:490-498, 2007.


  38. [FLOR-07b] L. Flórez Valencia, J. Montagnat, and M. Orkisz. 3D models for vascular lumen segmentation in MRA images and for artery-stenting simulation. Innov Tech Biol Med - RBM, 28(2):65-71, 2007.


  39. [FOLL-07] H. Follet, F. Peyrin, E. Vidal-Salle, A. Bonnassie, C. Rumelhart, and P.J. Meunier. Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography. J Biomech, 40(10):(2174-2183), 2007.


  40. [FROM-07] J. Fromageau, H. Liebgott, E. Brusseau, D. Vray, and P. Delachartre. Estimation of Time-Scaling Factor for Ultrasound Medical Images Using the Hilbert Transform. Eurasip J Adv Signal Proces, 2007:Article ID 80735, 13 pages, 2007.


  41. [GAMO-07] D. Gamondès, R. Tetreau, L. Boussel, E. Bonnefoy, and P. Staat. Innovations in emergency management of chest pain with CT angiography. Ann Fr Anesth Reanim, 26(12):1073-1077, 2007.


  42. [GELA-07] A. Gelas, O. Bernard, D. Friboulet, and R. Prost. Compactly supported radial basis functions based collocation method for level-set evolution in image segmentation. IEEE Trans Image Proces, 16(7):1873-1887, 2007.


  43. [GIAR-07] M. Giard, A. Lepape, B. Allaouchiche, C. Guérin, J.J. Lehot, M.O. Robert, G. Fournier, D. Jacques, D. Chassard, P.Y. Geugniaud, and F. Artru. Early and late onset ventilator-associated pneumonia acquired in the ICU: comparison of Risk factors. J Crit Care, 23(1):27-33, 2007.


  44. [GIFF-07] H.C. Gifford, P.E. Kinahan, C. Lartizien, and M.A. King. Evaluation of Multiclass Model Observers in PET LROC. IEEE Trans Nucl Sci, 54(1):116-123, 2007.


  45. [GRAV-07a] D. Graveron-Demilly and D. van Ormondt. Magnetic Resonance Spectroscopic Imaging. Toward Non-Invasive In Vivo Assessment of Metabolic Content. G.I.T. Laboratory Journal (Wiley), 2007?:29-31, 2007.


  46. [GUIG-07] J.P. Guigay, M. Langer, R. Boistel, and P. Cloetens. Mixed contrast transfer and transport of intensity approach for phase retrieval in the Fresnel region. Optics Letters, 32:1617-1619, 2007.


  47. [GUER-07b] C. Guérin, F. Bayle, S. Debord, J.C. Poupelin, M. Badet, S. Lemasson, and J.C. Richard. Viscoelastic properties of lungs and thoracic wall of anaesthetized mechanically ventilated piglets. Vet Anaesth Analg, 34:331-338, 2007.


  48. [GUER-07d] C. Guérin, T. Fassier, F. Bayle, S. Lemasson, and J.C. Richard. Inhaled bronchodilator administration during mechanical ventilation: how to optimize it ? and for which clinical benefit ?. J Aerosol Med, 21(1):85-96, 2007.


  49. [GUER-07c] C. Guérin, A. Levrat, S. Pontier, and G. Annat. A study of experimental acute lung injury in pigs on zero end-expiratory pressure. Vet Anaesth Analg, doi:10.1111:j.1467-2995.2007.00363.x, 2007.


  50. [GUER-07a] C. Guérin and J.C. Richard. Measurement of respiratory system resistance. Intensive Care Med, 33:1046-1049, 2007.


  51. [HAIA-07] G. Haiat, F. Padilla, F. Peyrin, and P. Laugier. Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a three-dimensional model simulation. J Bone Min Research, 22(5):665-674, 2007.


  52. [HAMO-07] H. Hamoudeh, A. Al Faraj, E. Canet-Soulas, F. Bessueille, D. Léonard, and H. Fessi. Elaboration of PLLA-based superparamagnetic nanoparticles: Characterization, magnetic behaviour study and in vitro relaxivity evaluation.. Int J Pharm, 338:248-257, June 2007.


  53. [HIBA-07b] B. Hiba, N. Richard, H. Thibault, and M. Janier. Cardiac and respiratory self-gated cine MRI in the mouse: comparison between radial and rectilinear techniques at 7T. Magn Reson Med, 58(4):(745-53), 2007.


  54. [LAMB-07] F. Lamberton, N. Delcroix, D. Grenier, B. Mazoyer, and M. Joliot. A new EPI-based dynamic field mapping method: Application to retrospective geometrical distortion corrections. J Magn Reson Imaging, 26(3):747-755, August 2007.


  55. [LART-07a] C. Lartizien, C. Kuntner, A.L. Goertzen, A.C. Evans, and A. Reilhac. Validation of PET-SORTEO Monte Carlo simulations for the geometries of the MicroPET R4 and Focus 220 PET scanners. Phys Med Biol, 52(1):4845-4862, 2007.


  56. [LEE-07] H.J. Lee, E. Truy, G. Mamou, D. Sappey-Marinier, and A.L. Giraud. Visual speech circuits in profound acquired deafness: A possible role for latent multimodal connectivity.. Brain, 130(Pt - 11):2929-2941, 2007.


  57. [LEMA-06e] S. Lemasson, P. Nesme, A. Herblanc, P. Beuret, C. Louerat, G. Bourdin, F. Vargas, J.C. Guérin, G. Hilbert, and C. Guérin. Changes in inspiratory capacity during acute respiratory failure in COPD patients. Rev Mal Respir, 24:314-322, 2007.


  58. [LIEB-07a] H. Liebgott, J.E. Wilhjelm, J.A. Jensen, D. Vray, and P. Delachartre. PSF dedicated to estimation of displacement vectors for tissue elasticity imaging with ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control, 54(4):746-756, 2007.


  59. [LOFF-07a] R. Loffroy, L. Boussel, F. Farhat, and P. Douek. Isolated floating thrombus of the thoracic aorta : a rare sign of trauma managed with anticoagulant therapy. Ann Thorac Surg, 84:1766, 2007.


  60. [MALA-07] O. Malaspinas, G. Courbebaisse, and M.O. Deville. Simulation of a generalized Newtonian fluid by the Lattice Boltzmann Method. Modern Physics C, 18(12):1939-1949, 2007.


  61. [MARI-07d] J.M. Mari and C. Cachard. Acquire real-time RF digital ultrasound data from a commercial scanner. Technical Acoustics, 2007.


  62. [MART-07] C. Martin, D. Grenier, M. Thevenet, M. Vigouroux, B. Bertrand, M. Janier, N. Ravel, and P. Litaudon. fMRI visualization of transient activations in the rat olfactory bulb using short odor stimulations. Neuroimage, 36:1288-1293, 2007.


  63. [MAST-07] M. Mastrogiacomo, A. Papadimitropoulos, A. Cedola, F. Peyrin, P. Giononni, S.G. Pearce, M. Alini, C. Giannini, A. Guagliardi, and R. Cancedda. Engineering of Bone using Bone Marrow Stromal Cells and a Silicon-Stabilized Tricalcium Phosphate Bioceramic: evidence for a coupling between Bone Formation and Scaffold Resorption. Biomaterials, 28(7):1376-1384, 2007.


  64. [MAUR-07] R.L. Maurice, J. Fromageau, E. Brusseau, G. Finet, G. Rioufol, and G. Cloutier. On the potential of Lagrangian estimator for endovascular ultrasound elastography: In vivo human coronary artery study. Ultrasound Med Biol, 33(8):1199-1205, 2007.


  65. [MIAO-07] P. Miao, B. Hiba, J.H. Luo, D. Sappey-Marinier, I.E. Magnin, and Y.M. Zhu. MR image reconstruction from partial k-space using singularity function representations. Comput Med Imag Graph, 571:239-242, 2007.


  66. [MILL-07] J Milles, Y.M. Zhu, G. Gimenez, C.R.G. Guttmann, and I.E. Magnin. MRI intensity nonuniformity correction using simultaneously spatial and gray-level histogram information. Comput Med Imag Graph, 31:81-90, 2007.


  67. [MILO-07] L. Milot, J. Dumortier, O. Boillot, and F. Pilleul. Giant aneurysm of the main hepatic artery secondary to hereditary hemorrhagic telangiectasia: 3D contrast-enhanced MR angiography features. Gastroenterol Clin Biol, 31:297-299, March 2007.


  68. [MONN-07] O. Monneuse, F. Pilleul, X. Barth, L. Gruner, B. Allaouchiche, P.J. Valette, and E. Tissot. Portal venous gas detected on computed tomography in emrgency situations: surgery is still necessary. World J Surg, 31(5):1065-1071, May 2007.


  69. [MONT-07] J. Montagnat, T. Glatard, and D. Lingrand. Texture-based Medical Image Indexing and Retrieval on Grids. Medical Imaging Technology, 25(5), November 2007.


  70. [NIGH-07a] N. Nighoghossian, M. Wiart, S. Cakmak, Y. Berthezène, L. Derex, T.H. Cho, C. Nemoz, F. Chappuis, J.L. Tisserand, J.B. Pialat, P. Trouillas, J.C. Froment, and M. Hermier. Inflammatory response after ischemic stroke: a USPIO-enhanced MRI study in patients. Stroke, 38(2):303-307, 2007.


  71. [PAOL-07] V. Paoli, M. Durieux-Courbière, J. Dumortier, and F. Pilleul. Portal dissection during TIPS placement. J Radiol, 88(5):687-688, May 2007.


  72. [PAPA-07] A. Papadimitropoulos, M. Mastrogiacomo, F. Peyrin, E. Molinari, V.S. Komlev, F. Rustichelli, and R. Cancedda. Kinetics of in vivo bone deposition by bone marrow stromal cells within a resorbable porous calcium phosphate scaffold: an X-ray computed microtomography study. Biotechnol Bioeng, 98(1):271-281, 2007.


  73. [PERR-07b] B. Perrenot, R. Vaillant, R. Prost, G. Finet, P. Douek, and F. Peyrin. Motion correction for coronary stent reconstruction from rotational x-ray projection sequences. IEEE Trans Med Imaging, 26(10):1412-1423, 2007.


  74. [PERR-07] A.L. Perrier, J.M. Duchamp, and P. Ferrari. A Small-sized Semi-lumped Three-port Tunable Power Divider. Microwave and Optical Technology Letters, 49(1):90-94, January 2007.


  75. [PEYR-07c] F. Peyrin. Three-dimensional image-based characterisation of porous media : application to bone micro-architecture. Osteoporosis Int, 18(6):837-839, 2007.


  76. [PEYR-07a] F. Peyrin, M. Mastrogiacomo, R. Cancedda, and R. Martinetti. SEM and 3D synchrotron radiation microtomography in the study of bioceramic scaffolds for tissue engineering applications. Biotechnol Bioeng, 97(3):638-348, 2007.


  77. [PEYR-07b] F. Peyrin, Z. Peter, A. Larrue, A. Bonnassie, and D. Attali. Three-dimensional image-based characterisation of porous media : application to bone micro-architecture. Image Anal Stereol, 26(3):179-185, Novembre 2007.


  78. [PIAL-07a] J.B. Pialat, T.H. Cho, O. Beuf, S. Moucharrafie, J.B. Langlois, C. Nemoz, M. Janier, Y. Berthezène, N. Nighoghossian, and M. Wiart. MRI monitoring of focal cerebral ischemia in peroxisome proliferator-activated receptor (PPAR)-deficient mice. Nuclear Magnetic Resonance in Biomedicine, 20(3):335-342, 2007.


  79. [PILL-07] F. Pilleul, M. De Queiros, M. Durieux, L. Milot, O. Monneuse, B. Floccard, and B. Allaouchiche. Radiological management of vascular lesions secondary to pelvic injuries. J Radiol, 88(5):639-646, May 2007.


  80. [PUECH-07a] P. Puech, L. Boussel, S. Belfkih, L. Lemaitre, P. Douek, and R. Beuscart. DicomWorks: Software for Reviewing DICOM Studies and Promoting Low-cost Teleradiology. J Digit Imaging, 20(10):122-130, 2007.


  81. [RABE-07a] H. Rabeson, H. Ratiney, F. Fauvelle, C. Cudalbu, S. Cavassila, A. Bernard, P. Giraudon, D. van Ormondt, and D. Graveron-Demilly. Quantitation for in vivo and ex vivo NMR Spectroscopy. J Optoelectron Adv M, 9:505-511, 2007.


  82. [RATI-07a] H. Ratiney, S.M. Noworolski, M. Sdika, R. Srinivasan, R.G. Henry, S.J. Nelson, and D. Pelletier. Estimation of metabolite T1 relaxation times using tissue specific analysis, signal averaging and bootstrapping from magnetic resonance spectroscopic imaging data. Magn Reson Mater Phy Biol Med, 20(3):143-155, 2007.


  83. [RAUM-07] K. Raum, T. Hofmann, I. Leguerney, A. Saied, F. Peyrin, L. Vico, and P. Laugier. Variations of microstructure, mineral density and tissue elasticity in B6/C3H mice. Bone, 41(6):1017-1024, 2007.


  84. [TOME-07a] A. Reilhac, S. Tomei, I. Buvat, C. Michel, C. Keheren, and N. Costes. Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies. Neuroimage, pp in-press, 2007.


  85. [RICH-07] J. C. Richard, F. Brégeon, V. Leray, D. Le Bars, N. Costes, C. Tourvieille, F. Lavenne, M. Devouassoux-Shisheboran, G. Gimenez, and C. Guérin. Effect of activated protein C on pulmonary blood flow and cytokine production in experimental acute lung injury. Intensive Care Med, 33(12):2199-2206, 2007.


  86. [RIOU-07] L.M. Riou, A. Broisat, C. Lartizien, M. C. Toufekstian, S. Maitrejean, M. Janier, G. Vanzetto, D. Fagret, and C. Ghezzi. Assessment of Non-Reperfused and Reperfused Myocardial Infarction using Diffusible or Deposited Radiolabelled Perfusion Imaging Agents. Eur J Nucl Med, 34(3):330-337, 2007.


  87. [ROBI-07b] M. Robini, A. Lachal, and I.E. Magnin. A Stochastic Continuation Approach to Piecewise Constant Reconstruction. IEEE Trans Image Proces, 16(10):2576-2589, 2007.


  88. [ROBI-07] M. Robini and I.E. Magnin. Radiographic Testing of Anomalies in Thick Metal Components: Fitting the Standard Line-Integral Model. IEEE Trans Nucl Sci, 54(4):1285-1297, 2007.


  89. [ROUC-07] Y. Rouchdy, J. Pousin, J. Schaerer, and P. Clarysse. A nonlinear elastic deformable template for soft structure segmentation: application to the heart segmentation in MRI. Inverse Problems, 23:1017-1035, 2007.


  90. [SABB-07] M. Sabbah, H. Alsaid, L. Fakri-Bouchet, A. Briguet, E. Canet-Soulas, and O. Fokapu. A Real Time Gating System for Mouse Cardiovascular MR Imaging. Magn Reson Med, 57:29-39, 2007.


  91. [SALO-07b] R. Salomir, M. Rata, C. Lafon, F. Cotton, A. S. Delemazure, J. Palussiere, and J. Y. Chapelon. Automatic feedback control of the temperature for MRI-guided therapeutic ultrasound. Conf Proc IEEE Eng Med Biol Soc, 2007:222-5, 2007.


  92. [SARR-07] D. Sarrut, B. Delhay, P.F. Villard, V. Boldea, M. Beuve, and P. Clarysse. A comparison framework for breathing motion estimation methods from 4D imaging. IEEE Trans Med Imaging, 26(12):1636-1648, 2007.


  93. [STUP-07a] V. Stupar, E. Canet-Soulas, S. Gaillard, H. Alsaid, N. Beckmann, and Y. Crémillieux. Retrospective Cine 3He ventilation imaging under spontaneous breathing conditions: a non-invasive protocol for small animal lung function imaging. Nuclear Magnetic Resonance in Biomedicine, 20:104-112, 2007.


  94. [SEVE-07b] P. Sève, C. Billotey, C. Broussolle, C. Dumontet, and J.R. Mackey. The role of 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography in disseminated carcinoma of unknown primary site. Magn Reson Med, 109(2):(292-299), 2007.


  95. [TARR-07] A. Tarroun, M. Bonnefoy, J. Bouffard-Vercelli, C. Gedeon, B. Vallée, and F. Cotton. Could linear MRI measurements of hippocampus differentiate normal brain aging in elderly persons from Alzheimer disease?. Surg Radiol Anat, 29(1):77-81, 2007.


  96. [TRUC-07] L. Truchot, N. Costes, L. Zimmer, B. Laurent, D. Le Bars, C. Thomas-Antérion, B. Croisile, B. Mercier, M. Hermier, A. Vighetto, and P. Krolak-Salmon. Up-regulation of hippocampal serotonin metabolism in mild cognitive impairment. Neurology, 69(10):(1012-7), 2007.


  97. [VALT-07a] S. Valton, F. Peyrin, P. Delpierre, F. Debarbieux, A. Bonissent, R. Khoury, C. Meessen, C. Morel, and D. Sappey-Marinier. Evaluation of tomographic reconstruction methods for small animal microCT and microPET/CT. Nucl Instr Meth Phys Res A, 571:278-281, 2007.


  98. [VELU-07] J. Velut, H. Benoit-Cattin, and C. Odet. Locally regularized Smoothing B-Snake. Eurasip J Adv Signal Proces, 2007(76241):Article ID 76241, 12 pages, 2007.


  99. [VIRE-07] L. Viremouneix, O. Monneuse, G. Gautier, L. Gruner, R. Giorgi, B. Allaouchiche, and F. Pilleul. Prospective evaluation of nonenhanced MR imaging in acute pancreatitis. J Magn Reson Imaging, 26(2):331-338, 2007.


  100. [WIAR-07c] M. Wiart, L. Curiel, A. Gelet, D. Lyonnet, J.Y. Chapelon, and O. Rouvière. Influence of perfusion on high-intensity focused ultrasound prostate ablation: a first-pass MRI study. Magn Reson Med, 58(1):119-127, 2007.


  101. [WIAR-07b] M. Wiart, N. Davoust, V. Desestret, N. Nighoghossian, and Y. Berthezène. Response to Letter by Bendszus, Kleinschnitz and Stoll: Iron-enhanced MRI in ischemic stroke: intravascular trapping vs cellular imaging. Stroke, 38:13, 2007.


  102. [WIAR-07e] M. Wiart, N. Davoust, J.B. Pialat, Y. Berthezène, and N. Nighoghossian. Magnetic resonance imaging (MRI) of inflammation in stroke. Conf Proc IEEE Eng Med Biol Soc, 2007:(4316-9), 2007.


  103. [WIAR-07a] M. Wiart, N. Davoust, J.B. Pialat, V. Desestret, S. Moucharrafie, T.H. Cho, M. Mutin, J.B. Langlois, O. Beuf, J. Honnorat, N. Nighoghossian, and Y. Berthezène. MRI monitoring of neuro-inflammation in mouse focal ischemia. Stroke, 38(1):131-137, 2007.


  104. [XIE-07a] K. Xie, J. Yang, and and Y.M. Zhu. Fast collision detection based on nose augmentation virtual surgery. Comput Meth Prog Bio, 88:1-7, 2007.


  105. [XIE-07c] K. Xie, J. Yang, and Y.M. Zhu. Interactive volume cutting of medical data. Comput Biol Med, 37:1155-1159, 2007.


  106. [XIE-07b] K. Xie, J. Yang, and Y.M. Zhu. Real time volume rendering of large datasets on standard PC hardware. Computer Applications, 27:1129-1131, 2007.


  107. [YANK-07] J. Yankam-Njiwa, Y.M. Zhu, M. Robini, and I.E. Magnin. Magnetic resonance image reconstruction analytic image representation. Nucl Instr Meth Phys Res A, 571(1-2):73-76, 2007.


  108. [ZYSS-07] J. Zyss, J. Xie-Brustolin, P. Ryvlin, S. Peysson, A. Beschet, D. Sappey-Marinier, M. Hermier, and S. Thobois. Epilepsia partialis continua with dystonic hand movement in a patient with a malformation of cortical development.. Mov Disord, 22(12):1793-1796, 2007.


Communications Proceedings
  1. [ADHA-07] M. Adham, F. Pilleul, V. Hervieu, A. Choukr, and C. Partensky. TIPMP de type canal principal avec lésions bifocales discontinues (skip lésions) : traitements chirurgicales. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  2. [ALFA-07b] A. Al Faraj, M. Hamoudeh, H. Fessi, and E. Canet-Soulas. Nanoparticules de PLLA dopées en oxyde de fer: un nouvel agent diagnostique et thérapeutique pour le suivi des tumeurs musculaires.. In Journées de Recherche en Imagerie Médicale - JRIM, Dijon, France, 2007.


  3. [ALFA-07a] A. Al Faraj, G. Lacroix, H. Alsaid, D. Elgrabi, V. Stupar, F. Robidel, S. Gaillard, E. Canet-Soulas, and Y. Crémillieux. Longitudinal Helium-3 and Proton imaging of magnetite biodistribution in a rat model of instilled nanoparticles.. In International Society of Magnetic Resonance in Medicine, Berlin, Germany, 2007.


  4. [AOUD-07a] W. Aoudi and D. Vray. Un estimateur de vitesse basé sur la variance temporelle locale de l'intensité dans une séquence d'images ultrasonores. In Colloque GRETSI, Troyes, France, pages 157-160, Septembre 2007.


  5. [BABO-07b] L. Baboi, L. Milot, C. Lartizien, C. Roche, F. Pilleul, J.Y. Scoazec, and O. Beuf. Characterization of Neuro-Endocrine Tumors in an Athymic Nude Mouse Model Using Dedicated Synchronization Strategies for T2-Weigted MR Imaging at 7T. In 29th IEEE EMBS Annual International Conference, Lyon, France, 2007.


  6. [BABO-07a] L. Baboi, L. Milot, C. Lartizien, C. Roche, J.Y. Scoazec, F. Pilleul, and O. Beuf. Characterization of neuro-endocrine tumors in an athymic nude mouse model using dedicated synchronization strategies for T2-weigted MR imaging at 7T. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 2879-2882, 2007.


  7. [BADE-07] J.N. Badel, D. Sarrut, and C. Ginestet. Prediction of portal dose images with Monte Carlo simulation for dosimetric control in radiotherapy. In International Conference on the Use of Computers in Radiation Therapy (ICCR), Toronto, Canada, June 2007.


  8. [BAGO-07a] M. Bagory, F. Durand-Dubief, Ibarrola, C. D. Confavreux, and D. Sappey-Marinier. Absolute quantification in magnetic resonance spectroscopy: Validation of a clinical protocol in multiple sclerosis. In Conf Proc IEEE Eng Med Biol Soc, volume 2007, pages 3458-3461, 2007.


  9. [BALO-07b] S. Balocco, O. Basset, G. Courbebaisse, E. Boni, A. Frangi, P. Tortoli, and C. Cachard. Estimation of visco-elastic properties of the vascular wall using simultaneous velocity and displacement measurements with Doppler Ultrasound: in vitro evaluation. In International Congress on Ultrasonics, Vienna, Austria, April 2007.


  10. [BALT-07] M. Baltaxe Milwer, L. Flórez Valencia, M. Hernández Hoyos, I.E. Magnin, and M. Orkisz. Fast marching contours for the segmentation of vessel lumen in CTA cross-sections. In Conf Proc IEEE Eng Med Biol Soc, Lyon, France, pages 791-794, 2007. IEEE.


  11. [BAO-07] L. Bao, Y.M. Zhu, W.Y. Liu, M. Robini, Z. Pu, and I.E. Magnin. Analysis of cardiac diffusion tensor magnetic resonance images using sparse representation. In Proc. 29th Int. Conf. IEEE EMBS, Lyon, France, pages 4516-4519, 2007.


  12. [BASA-07c] A. Basarab, W. Aoudi, H. Liebgott, D. Vray, and P. Delachartre. Parametric deformable block matching for ultrasound imaging. In IEEE International Conference on Image Processing ICIP'07, San Antonio, USA, pages II-429-II-432, September 2007.


  13. [BASA-07b] A. Basarab, C. Grava, V. Buzuloiu, and P. Delachartre. Estimation de décalages subpixéliques par ajustement de la phase des signaux complexes. In Gretsi, Troyes, France, pages 149-152, September 2007.


  14. [BASA-07a] A. Basarab, P. Gueth, H. Liebgott, and P. Delachartre. Two-dimensional least-squares estimation for motion tracking in ultrasound elastography. In IEEE EMBC, Lyon, France, pages 2155-2158, August 2007.


  15. [BAXA-07a] N. Baxan, A. Rengle, G. Pasquet, J.F. Châteaux, A. Briguet, P. Morin, and L. Fakri-Bouchet. Limit of detection of cerebral metabolites by localised NMR spectroscopy. In GERM, Alénya, France, 2007.


  16. [BAYL-07] F. Bayle, S. Debord, J.C. Richard, M. Badet, S. Lemasson, J.C. Poupelin, and C. Guérin. Prédiction de la recrutabilité pulmonaire par la PEP à partir des courbes pression-volume inspiratoires et expiratoires trans-pulmonaire à débit lent continu dans un modèle porcin d'agression pulmonaire aigu. In Reanimation, Congrès SRLF 2007, pages 16:S 66, 2007.


  17. [BERN-07b] O. Bernard, B. Touil, A. Gelas, R. Prost, and D. Friboulet. A RBF-based multiphase level set method for segmentation in echocardiography using the statistics of the radiofrequency signal. In IEEE International Conference on Image Processing ICIP'07, volume 3, pages 157-160, 2007.


  18. [BERN-07a] O. Bernard, B. Touil, A. Gelas, R. Prost, and D. Friboulet. Segmentation of myocardial regions in echocardiography using the statistics of the radio-frequency signal. In Functional Imaging and Modeling of the Heart, FIMH'07, volume 4466 of Lect Notes Comput Sc, Salt Lake City, UT, USA, pages 433-442, June 2007. Springer Verlag, Publ..


  19. [BILL-07] C. Billet and R. Sablong. Differential optical spectroscopy for absorption characterization of mono / two-layered scattering media. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 2622-2625, 2007.


  20. [BOHI-07] S. Bohic, P. Cloetens, J. P. Guigay, L. Helfen, O. Hignette, M. Langer, W. Ludwig, R. Mokso, and C. Morawe. Combined Projection Microscopy and Fluorescence Micro-analysis using Multilayer Coated KB-optics. In International Workshop on Phase Retrieval and Coherent Scattering - COHERENCE 2007, Monterey, USA, pages 45, 2007.


  21. [BOLD-07] V. Boldea, G.C. Sharp, S.B. Jiang, and D. Sarrut. Lung motion modeling with deformable registration: non-linearity and hysteresis estimation and analysis. In International Conference on the Use of Computers in Radiation Therapy (ICCR), Toronto, Canada, June 2007.


  22. [BOUR-07b] G. Bourdin, J. Barbier, J.F. Burle, G. Durante, S. Passant, B. Vincent, M. Badet, F. Bayle, T. Fassier, S. Lemasson, J.C. Richard, and C. Guérin. Description de la pratique de réhabilitation locomotrice et respiratoire au sein d'un service de réanimation médicale. In Réanimation, Congrès SRLF 2007, pages 16:S 07, 2007.


  23. [BOUR-07a] G. Bourdin, J. Barbier, J. Burle, G. Durante, S. Passant, B. Vincent, F. Bayle, S. Lemasson, J. C. Richard, and C. Guérin. Early physical activity in patients undergoing mechanical ventilation in ICU. In Intensive Care Med, pages 33(S2)S 262, 2007.


  24. [BRUS-07] E. Brusseau, J.F. Déprez, F. Duboeuf, and O. Basset. Locally regularized strain field estimation for freehand elastography. In Proc. 29th Int. IEEE EMBC 2007, Lyon, France, pages 75-78, 2007.


  25. [CANA-07] L. Canaple, O. Beuf, M. Armenean, J. Hasserodt, M. Janier, and J. Samarut. Screening of active paramagnetic molecules in zebrafish embryos by MRI. In Second International Conference of the European Society for Molecular Imaging, Naples, Italy, June 14-15 2007.


  26. [CANT-07a] D. Cantor Rivera, M. Orkisz, and M. Hernández Hoyos. Generación de modelos arteriales tridimensionales a partir de imágenes de resonancia magnética (IRM). In XXXIII Conferencia Latinoamericana de Informática (CLEI), San José, Costa Rica, 2007. UNED, PEM, Oficina de Audiovisuales, ISBN: 978-9968-9678-9-1.


  27. [CANT-07b] D. Cantor Rivera, M. Orkisz, L.F. Uriza, and M. Hernández Hoyos. Generación de modelos arteriales tridimensionales a partir de imágenes de resonancia magnética (IRM). In XXXII Congreso Colombiano de Radiologìa, Cartagena de Indias, Colombia, 2007.


  28. [CANT-07d] D. Cantor Rivera, M. Orkisz, L .F. Uriza Carrasco, and M. Hernández Hoyos. Generación de modelos vasculares especìficos al paciente a partir de IRM 3D usando el algoritmo de fast-marching. In Cuarto Seminario de Ingenierìa Biomédica y Quinto Seminario Internacional de Procesamiento de y Análisis de Imágenes Médicas, Bogota, Colombia, pages 2 in electronic proc., November 2007.


  29. [CHO-07b] J.W. Cho, M.S. Kim, S. Valette, H.Y. Jung, and R. Prost. A 3D meshes sequence coding using the combination of spatial and temporal wavelet analysis. In International conference on Computer Vision, Computer Graphics Collaboration Techniques and Application (MIRAGE'07), volume 4418 of Lect Notes Comput Sc, Rocquencourt, France, pages 389-399, March 2007. Springer Verlag, Publ..


  30. [COEL-07] C.S. Coello, J.M. Dinten, M. Arques, P. Rohr, and C.Odet. Dual-energy technique for digital flat-panel detectors without x-ray tube voltage switching. In Medical Imaging 2007 : Physics of Medical Imaging, 2007. SPIE, SPIE.


  31. [RATI-07c] B. Cree, H. Ratiney, M. Owen, A. Evangelista, J. Oh, and D. Pelletier. Magnetic resonance spectroscopy effects of natalizumab:single center results from the SENTINEL study. In American Academy of Neurology 59th Annual Meeting, Boston, USA, May 2007.


  32. [CUDA-07d] C. Cudalbu, A. Bucur, D. Graveron-Demilly, O. Beuf, and S. Cavassila. Comparison of two strategies of background-accommodation: Influence on the metabolite concentration estimation from in vivo Magnetic Resonance Spectroscopy data. In Conf Proc IEEE Eng Med Biol Soc, volume 1, Lyon, France, pages 2077-2080, 2007.


  33. [CUDA-07] C. Cudalbu, S. Cavassila, H. Rabeson, D. van Ormondt, and D. Graveron-Demilly. Influence of the background-handling strategy on the metabolite concentration estimates. In International Society of Magnetic Resonance in Medicine - European Society of Magnetic Resonance in Medicine and Biology, Berlin, Germany, pages 3170, May 2007.


  34. [CUDA-07c] C. Cudalbu, A. Montavont, P. Ryvlin, and S. Cavassila. Brain metabolite concentration estimates using Magnetic Resonance Spectroscopy in a chronic model of temporal lobe epilepsy. In GERM, Alénya, France, pages 46, Mars 2007.


  35. [CUDA-07b] C. Cudalbu, A. Rengle, O. Beuf, and S. Cavassila. Rat brain metabolite relaxation time estimates using Magnetic Resonance Spectroscopy at two different field strengths. In GERM, Alénya, France, pages 47, Mars 2007.


  36. [CUDA-07a] C. Cudalbu, A. Rengle, A. Bucur, O. Beuf, and S. Cavassila. In Vitro and In Vivo Relaxation Times of N-acetylaspartate, Creatine and Choline at 4.7T and 7T. In International Society of Magnetic Resonance in Medicine - European Society of Magnetic Resonance in Medicine and Biology, Berlin, Germany, pages 2924, May 2007.


  37. [STEF-07] D. Dan Stefan, M.E Cabañas, S. Van Huffel, and D. Graveron. JMRUI - A program for the time-domain analysis of in vivo MR data. In Proceedings of the EUROMAR2007 Meeting, Tarragona, Spain, July 2007.


  38. [GUIO-07a] F. De Guio, H. Benoit-Cattin, and A. Davenel. Characterization of signal loss due to magnetic susceptibility interfaces in gradient echo imaging by simulations and experiments. In EUROMAR'07, Tarragona, Espagne, June 2007.


  39. [GUIO-07b] F. De Guio, H. Benoit-Cattin, and A. Davenel. Quantitative study of the signal decay due to magnetic susceptibility interfaces: MRI simulations and experiments. In IEEE EMBC'07, Lyon, France, August 2007.


  40. [DEBO-07] P.J. Debouttière, S. Roux, F. Vocanson, C. Billotey, O. Beuf, R. Lamartine, P. Perriat, and O. Tillement. Gold nanoparticles for MRI. In International Society of Magnetic Resonance in Medicine - European Society of Magnetic Resonance in Medicine and Biology, Berlin, Germany, 19-25 May 2007.


  41. [DELH-07] B. Delhay, P. Clarysse, and I.E. Magnin. Locally adapted spatio-temporal deformation model for dense motion estimation in periodic cardiac image sequences. In Functional Imaging and Modeling of the Heart, volume LNCS 4466, Salt Lake City, UT, USA, pages 393-402, June 2007.


  42. [DESE-07a] V. Desestret, J.C. Brisset, E. Devillard, S. Moucharrafie, M. Tappaz, S. Nataf, N. Nighoghossian, Y. Berthezène, and M. Wiart. Early stages investigation of USPIO-induced signal loss after focal cerebral ischemia in mice. In Contrast Media Research Symposium, Banff, Canada, 2007.


  43. [DUBO-07] F. Duboeuf, H. Liebgott, A. Basarab, E. Brusseau, P. Delachartre, and D. Vray. Static mechanical assessment of elastic Young's modulus of tissue mimicking materials used for medical imaging. In Proc. 29th Int. IEEE EMBC 2007, Lyon, France, pages 3450-3453, 2007.


  44. [DUCR-07] N. Ducros, A. Da Silva, J.M. Dinten, and F. Peyrin. A simulation-based study of reconstruction in Time-resolved Fluorescence Diffuse Optical Tomography in Cylindrical geometry. In Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pages 2639-2642, Aug. 2007.


  45. [DEPR-07] J.F. Déprez, G. Cloutier, C. Schmitt, C. Gehin, A. Dittmar, O. Basset, and E. Brusseau. 3D Ultrasound Elastography for Early Detection of Lesions. Evaluation on a Pressure Ulcer Mimicking Phantom. In Proc. 29th Int. IEEE EMBC 2007, Lyon, France, pages 79-82, 2007.


  46. [ESCO-07] R. Escola, S. Bonnet, I.E. Magnin, and R. Guillemaud. Wavelet-based scale-dependent detection of neurological action potentials. In 29th Annual International Conference of the IEEE EMBS, Lyon, 2007.


  47. [FALC-07] J. Falconet, R. Sablong, E. Perrin, F. Jaillon, and H. Saint-Jalmes. Backscattered stokes vectors of turbid media: anisotropy factor and reduced scattering coefficient estimation. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 1619-1622, 2007.


  48. [FAUV-07] F. Fauvelle, G. Testylier, H. Rabeson, D. Graveron-Demilly, A. Foquin, P. Carpentier, and F. Dorandeu. Evolution of Mouse Brain Metabolism after a Convulsive Dose of Soman. In Proc. Int. Soc. Magnetic Resonance in Medicine and European Society for Magnetic Resonance in Medicine and Biology, Joint Annual Meeting ISMRM-ESMRMB, Berlin, Germany, pages 2416, May 2007.


  49. [FLOR-07a] L. Flórez Valencia, M. Baltaxe Milwer, M. Hernández Hoyos, F. Vincent, P. Douek, I.E. Magnin, and M. Orkisz. Fast marching level-sets for the extraction of vascular cross-sectional contours in CT angiography images. In 21st CARS - Comput Assist Radiol Surg, volume 2-suppl.1 of Int J Comp Assist Radiol Surg, Berlin, Germany, pages S449-S450 (abstract), 2007. Springer.


  50. [FRIN-07] C. Frindel, M. Robini, S. Rapacchi, E. Stephant, Y.M. Zhu, and P. Croisille. Towards in vivo diffusion tensor MRI on human heart using edge-preserving regularization. In Proc. 29th Int. Conf. IEEE EMBS, Lyon, France, pages 6007-6010, 2007.


  51. [GELA-07a] A. Gelas, J. Schaerer, O. Bernard, D. Friboulet, P. Clarysse, I.E. Magnin, and R. Prost. Radial Basis Functions Collocation Methods For Model-Based Level-set Segmentation. In IEEE International Conference on Image Processing (ICIP), volume 2, San Antonio, TX, USA, pages 237-240, September 2007.


  52. [GHAZ-07a] B. Ghazal, M. Khachab, C. Cachard, D. Friboulet, and C. Mokbel. Autoregressive modelling application for vascular zones detection in the contrast echographic images. In ISSPA, Dhubai, United Emirates, April 2007.


  53. [GHAZ-07b] B. Ghazal, M. Khachab, C. Cachard, D. Friboulet, and C. Mokbel. Classification of the Vascular Contrast Ultrasound Images using Autoregressive Model Coupled to Gaussian Mixture Model. In Conf Proc IEEE Eng Med Biol Soc, Lyon, France, pages 331-334, August 2007.


  54. [GLAT-2007a] Tristan Glatard, Diane Lingrand, Johan Montagnat, and Michel Riveill. Impact of the execution context on Grid job performances. In International Workshop on Context-Awareness and Mobility in Grid Computing (WCAMG'07) (CCGrid'07), Rio de Janeiro, Brazil, pages 713-718, May 2007. IEEE.


  55. [GLAT-2007b] Tristan Glatard, Johan Montagnat, and Xavier Pennec. Optimizing jobs timeouts on clusters and production grids. In International Symposium on Cluster Computing and the Grid (CCGrid'07), Rio de Janeiro, Brazil, pages 100-107, May 2007. IEEE.


  56. [GOUT-07b] F. Goutailler, V. Stupar, S. Gaillard, B. Montcel, and Y. Crémillieux. Hyperpolarisation de noyaux de C13 par Polarisation Dynamique Nucléaire pour la production d'agents de contraste pour l'IRM et la SRM biomédicales : principes, conception et implémentation. In Congrès général de la Société Française de Physique, Grenoble, France, July 2007.


  57. [GOUT-07c] F. Goutailler, V. Stupar, B. Montcel, and Y. Crémillieux. A Dynamic Nuclear Polarization system for MRI and MRS in vivo hyperpolarised contrast agents: Principles, design and realisation. In Dynamic Nuclear Polarization Symposium, Nottingham, United Kingdom, August 2007.


  58. [GOUT-07a] F. Goutailler, V. Stupar, B. Montcel, S. Gaillard, and Y. Crémillieux. Hyperpolarisation de noyaux de C13 par Polarisation Dynamique Nucléaire (PDN) pour la production d'agents de contraste pour l'IRM et la SRM biomédicales. In XXéme Congrès du GERM, Alénya, France, March 2007.


  59. [GREN-07] D. Grenier, L. Milot, X. Peng, F. Pilleul, and O. Beuf. A Magnetic Resonance Elastography (MRE) approach for liver investigation. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 2607-2610, 2007.


  60. [GUET-07] P. Gueth, A. Basarab, H. Liebgott, and P. Delachartre. Beamforming techniques for motion estimation in ultrasound elastography. In IEEE International Ultrasonics Symposium, New-York, USA, pages 1953-1956, October 2007.


  61. [GUER-07i] C. Guérin, P. Couder, J.C. Richard, T. Fassier, F. Bayle, M. Badet, S. Lemasson, V. Urrea, A. Saez, and T. Boyer. Effet sur la durée de vie du filtre des cathéters Hickman ou Haemoaccess insérés en veine fémorale pour hémo(dia)filtration veinoveineuse continue en réanimation. In Reanimation, Congrès SRLF 2007, pages 16:S 121, 2007.


  62. [GUER-07j] C. Guérin, T. Fassier, F. Bayle, S. Lemasson, B. Poggi, and J.C. Richard. Acid-base balance in patients with acute on chronic respiratory failure and ARDS. In Intensive Care Med, pages 33 (S2) S 142, 2007.


  63. [HADD-07] R. Haddad, I.E. Magnin, and P. Clarysse. A new fully-digital anthropomorphic and dynamic thorax/heart model. In Proceedings of the 29th Annual International Conference of the IEEE EMBS, Lyon, France, pages 5999-6002, August 2007.


  64. [IBAR-07] D. Ibarrola, A. Vighetto, M. Hermier, P. Krolak-Salmon, J.C. Froment, and D. Sappey-Marinier. Diagnosis and first study of therapy follow-up of Creutzfeldt-Jakob disease by Magnetic Resonance Diffusion and Spectroscopy. In Fithteen Int. Soc. Magn. Ron. Med., Berlin, Allemagne, 2007.


  65. [LANG-07b] M. Langer, P. Cloetens, J. P. Guigay, S. Valton, and F. Peyrin. Quantitative comparison of phase retrieval methods in in-line phase tomography. In COHERENCE 2007: International workshop on phase retrieval and coherent scattering, pages (abstract), 2007.


  66. [LANG-07a] M. Langer, P. Cloetens, J.P. Guigay, S. Valton, and F. Peyrin. Quantitative evaluation of phase retrieval algorithms in propagation based phase tomography. In IEEE International Symposium on Biomedical Imaging (ISBI), Arlington, USA, pages 552-555, 2007.


  67. [LARR-07b] A. Larrue, D. Attali, and F. Peyrin. Segmentation géométrique d'images 3D basée sur des techniques de squelettisation. In Colloque GRETSI, Troyes, France, 2007.


  68. [LARR-07a] A. Larrue, A. Rattner, N. Laroche, L. Vico, and F. Peyrin. Feasibility of Micro-Crack Detection in Human Trabecular Bone Images from 3D Synchrotron Microtomography. In Conf Proc IEEE Eng Med Biol Soc, Lyon, France, 2007.


  69. [LART-07] C. Lartizien, S. Tomei, V. Maxim, and C. Odet. Combining a wavelet transform with a channelized Hotelling observer for tumor detection in 3D PET oncology imaging. In SPIE Medical Imaging Conference, number 6515, San Diego, USA, pages 1-10, 2007.


  70. [LEE-07b] H.J. Lee, E. Truy, D. Sappey-Marinier, and A.L. Giraud. Enhanced visual speech neural activity in profound deafness without cross-modal plasticity. In Human Brain Mapping, 13th annual meeting, Chicago, USA, 2007.


  71. [LEE-07c] H.J. Lee, E. Truy, D. Sappey-Marinier, and A.L. Giraud. Speech-reading in post-lingual deaf. In Objective Measures in Cochlear and Brainstem Implants Conference, Varese, Italy, 2007.


  72. [LEMA-07] S. Lemasson, B. Rajon, T. Cotte, P. Nesme, L. Ayzac, J. Demaziére, and C. Guérin. Etude rétrospective de la pratique de la ventilation non invasive pour insuffisance respiratoire aiguë dans l'unité d'hospitalisation de courte durée d'un service d'urgence. In Reanimation, Congrès SRLF 2007, pages 16:S 130, 2007.


  73. [LIEB-07b] H. Liebgott, O. Bernard, C. Cachard, and D. Friboulet. Field simulation parameters design for realistic statistical parameters of Radio-Frequency ultrasound images. In IEEE International Ultrasonics Symposium, New-York, USA, pages 2247-2250, October 2007.


  74. [LIU-07] W.Y. Liu, Y.L. Zhang, W.H. Liu, S. Hu, Y.M. Zhu, and I.E. Magnin. A robust algorithm based on nonstationary degree for ultrasonic data enhancement. In IEEE Int. Conf. on Systems, Man and Cybernetics, Montreal, Que., Canada, pages 1061-1066, 2007.


  75. [MARI-07a] J.M. Mari, H. Liebgott, and C. Cachard. Ultrasonic scanning of micro needle in biological tissues. In International Congress on Ultrasonics, Vienna, Austria, April 2007.


  76. [MARI-07b] A. Marion, A. Needles, and D. Vray. Blood Velocity Estimation Based On 3D Spatiotemporal Filtering Of Sequences Of Ultrasound Images. In IEEE International Ultrasonics Symposium, New-York, USA, pages 2461-2464, October 2007.


  77. [MARI-07c] A. Marion and D. Vray. Filtrage spatiotemporel de séquences d'images ultrasonores pour l'estimation d'un champ dense de vitesses. In Colloque GRETSI, Troyes, France, pages 73-76, Septembre 2007.


  78. [MILO-07e] L. Milot, L. Baboi, O. Beuf, C. Lartizien, J.Y. Scoazec, and F. Pilleul. Suivi longitudinal par IRM de métastases hépatiques de tumeurs neuro-endocrine chez la souris nude. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  79. [MILO-07d] L. Milot, J. Dumortier, N. Mennesson, P.J. Valette, and F. Pilleul. Le TIPS chez le patient cirrhotique avec ascite réfractaire : existe-t'il des facteurs pronostiques de thrombose ?. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  80. [MILO-07a] L. Milot, M. Lapalus, J. Chayvialle, F. Pilleul, and P.J. Valette. Entéroscanner avec opacification hydrique : outil diagnostic en cas de suspicion de tumeurs de l'intestin grêle ?. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  81. [MILO-07b] L. Milot, O. Monneuse, B. Allaouchiche, Gruner L., and F. Pilleul. La stratégie thérapeutique de l'ulcère gastro-duodénal perforé peut-elle être orientée par une tomodensitométrie abdominale initiale. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  82. [MILO-07c] L. Milot, O. Monneuse, J. Chayvialle, P.J. Valette, and F. Pilleul. Apport du scanner multi-détecteurs dans la prise en charge des hémorragies digestives basses aigues. In Société Nationale Française de Gastro-Entérologie, Paris, France, 2007.


  83. [NEMO-2007] Clémentine Nemo, Tristan Glatard, Mireille Blay-Fornarino, and Johan Montagnat. Merging overlapping orchestrations: an application to the Bronze Standard medical application. In International Conference on Services Computing (SCC 2007), Salt Lake City, Utah, USA, pages 364-371, July 2007. IEEE Computer Engineering.


  84. [NICO-07] S. Nicolas, J. Dardenne, T. Paquet, and L. Heutte. Document Image Segmentation Using a 2D Conditional Random Field Model. In Proceedings of the Ninth International Conference on Document Analysis and Recognition, ICDAR, volume 1, Curitiba, Brazil, pages 407-411, 2007.


  85. [NIGH-07] N. Nighoghossian, M. Wiart, Y. Berthezène, T.H. Cho, S. Cakmak, L. Derex, J.C. Froment, P. Trouillas, and M. Hermier. Assessment of inflammatory response after ischemic stroke: Ultrasmall particles of iron oxide enhanced magnetic resonance study in patients. In Stroke, volume 38, San Francisco, California, USA, pages 566-567, 2007.


  86. [OULM-07] F. Oulmane, V. Detti, D. Grenier, E. Perrin, and H. Saint-Jalmes. Radiofrequency power deposition near metallic wires during MR imaging: feasibility study using T1-weighted thermal imaging. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 3894-3897, 2007.


  87. [PAVA-07] K. Pavaday, P. Couder, A. Saez, V. Urrea, T. Boyer, M. Badet, J.C. Richard, F. Bayle, S. Lemasson, T. Fassier, N. Loughraieb, and C. Guérin. Faisabilité de l'hémofiltration veino-veineuse continue avec le set Prisma ST100 prédilution : étude pilote monocentrique, ouverte, avec comparaison à un groupe de contrôle historique. In Reanimation, Congrès SRLF 2007, pages 16:S 120, 2007.


  88. [PAZO-07] M. Pazovic, N. De Jong, T. van der Steen, C. Cachard, and O. Basset. Imaging B/A sound velocity image. In International Congress on Ultrasonics, Vienna, Austria, April 2007.


  89. [PERR-07g] B. Perrenot, R. Vaillant, P. Douek, R. Prost, F. Peyrin, and G. Finet. An Automatic Calibration Approach For Left Ventricular Volume Assessment. In IEEE EMBC 2007, volume 4460-4463, 2007.


  90. [PERR-07c] B. Perrenot, R. Vaillant, L. Gavit, H. Motoya, P. Douek, R. Prost, G. Finet, and F. Peyrin. 3D Motion Compensated Tomographic Reconstruction of Coronary Stents from X-ray Rotational Sequence : An Experimental Study. In IEEE EMBC 2007, volume 735-738, 2007.


  91. [PERR-07a] B. Perrenot, R. Vaillant, R. Prost, G. Finet, P. Douek, and F. Peyrin. Quantitative Analysis of 3D Stent Reconstruction from a Limited Number of Views in Cardiac Rotational Angiography. In Medical Imaging 2007 : Physics of Medical Imaging, volume 6510, San Diego, CA, USA, pages 65104V1-65104V8, February 17-22 2007. SPIE.


  92. [PERR-07e] A.L. Perrier, J.M. Duchamp, and P. Ferrari. Adaptateur d'impédance accordable. In Journées Nationales Microondes, Toulouse, France, Mai 2007.


  93. [PERR-07f] A.L. Perrier, J.M. Duchamp, and P. Ferrari. Diviseur de puissance accordable. In Journées Nationales Microondes, Toulouse, France, Mai 2007.


  94. [PERR-07d] A.L. Perrier, T. Sharjalani, J.M. Duchamp, P. Ferrari, and A. El-Helwani. Diviseur/combineurs de puissance miniature et accordable. In Journées Nationales Microondes, Toulouse, France, Mai 2007.


  95. [PETE-07] Z. Peter, V. Bousson, C. Bergot, and F. Peyrin. Segmentation of low-contrast features in bone micro-CT images by a constraint region growing approach based on watershed. In IEEE International Symposium on Biomedical Imaging (ISBI), Washington DC, USA, pages 968-971, 2007.


  96. [PETI-07] T. Petitjean, F. Philit, B. Langevin, M. Germain-Pastenne, and C. Guérin. Evolution du sommeil et des grandeurs respiratoires au cours du sevrage de la ventilation non invasive chez l'insuffisant respiratoire chronique. In Reanimation, Congrès SRLF 2007, pages 16:S 171, 2007.


  97. [PEYR-07d] F. Peyrin, Z. Peter, A. Larrue, A. Bonnassie, and D. Attali. Three-dimensional image-based characterisation of porous media : application to bone micro-architecture. In Int Conf on Stereology, Saint-Etienne, France, 2007.


  98. [POPA-07] E. Popa, H. Rabeson, D. van Ormondt, and D. Graveron-Demilly. Lineshape Accommodation in Quantitation of Magnetic Resonance Spectroscopy Signals. In Proceedings of the 18th Annual Workshop on Circuits, Systems and Signal Processing (ProRISC 2007), Veldhoven, the Netherlands, pages 250 - 253, November 2007.


  99. [RABE-07] H. Rabeson, H. Ratiney, E. Capobianco, D. van Ormondt, and D. Graveron-Demilly. Is spending extra scan time on measuring a 'macromolecules-only' signal worthwhile?. In International Society of Magnetic Resonance in Medicine - European Society of Magnetic Resonance in Medicine and Biology, Joint Annual Meeting ISMRM-ESMRMB, Berlin, Germany, pages 2007, May 2007.


  100. [RABE-07b] H. Rabeson, H. Ratiney, D. van Ormondt, and D. Graveron-Demilly. Semi-Parametric Estimation in Magnetic Resonance Spectroscopy: Automation of the Disentanglement Procedure. In Proc. 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBS 2007, pages 662-665, 2007.


  101. [RACO-07] D. Racoceanu, H. Benoit-Cattin, and al.. ONCO-MEDIA: ONtology and COntext related MEdical image Distributed Intelligent Access. In HealthGrid'07, Geneve, Suisse, 2007.


  102. [RATI-07d] H. Ratiney, S. Chung, R.G. Henry, R. Srinivasan, S.J. Nelson, and D. Pelletier. Bootstrap in MRSI: a non-parametric way to assess quantification standard errors. In Int. Soc. Magnetic Resonance in Medicine, 15th Scientific Meeting and Exhibition, Berlin, Germany, May 2007.


  103. [RATI-07b] H. Ratiney, R. Srinivasan, R.G. Henry, D. Okuda, S.J. Nelson, and D. Pelletier. Early and Progressive Disease Marker in MS; results from a large cross-sectional spectroscopic imaging study at 3T. In American Academy of Neurology 59th Annual Meeting, Boston, USA, May 2007.


  104. [RENG-07a] A. Rengle, M. Armenean, R. Bolbos, J.C. Goebel, H. Saint-Jalmes, A. Pinzano-Watrin and, P. Gillet, and O. Beuf. A dedicated two-element phased array receiver coil for high resolution MRI of rat knee cartilage at 7T. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 3886-3889, 2007.


  105. [RENG-07] A. Rengle, L. Baboi, H. Saint-Jalmes, R. Sablong, and O. Beuf. Optical cardiac and respiratory device for synchronized MRI on small animal. In Conf Proc IEEE Eng Med Biol Soc, volume 1, pages 2046-2049, 2007.


  106. [RICH-07b] J.C. Richard, F. Brégeon, V. Leray, D. Le Bars, N. Costes, C. Tourevieille, F. Lavenne, M. Devouassoux, and C. Guérin. Effets de la protéine C activée recombinante sur la distribution de la perfusion pulmonaire étudiée en TEP au cours de l'agression pulmonaire expérimentale. In Reanimation, Congrès SRLF 2007, pages 16:S 63, 2007.


  107. [RICH-07c] J.C. Richard, C. Pouzot, A. Gros, D. Le Bars, C. Tourevieille, F. Lavenne, I. Frerichs, and C. Guérin. Comparison of electrical impedance tomography (EIT) and positron emission tomography (PET) to measure alveolar ventilation and volume. In Intensive Care Med, pages 33(S2)S 241, 2007.


  108. [RIDE-07] C. Ridereau-Zins, C. Aubé, F. Pilleul, Y. Gandon, M. Pierredon-Foulongne, and P.J. Valette. Assessment of the Water Enema: Computed Tomography - An Effective Imaging Technique for the Diagnosis of Colon Cancer. In RSNA, Chicago, USA, November 25-30 2007.


  109. [RIT-07b] S. Rit, C. Ginestet, and D. Sarrut. Comparison of gated and dynamic cone-beam CT reconstruction methods. In International Conference on the Use of Computers in Radiation Therapy (ICCR), Toronto, Canada, June 2007.


  110. [RIT-07] S. Rit and D. Sarrut. Cone-beam projection of a deformable volume for motion compensated algebraic reconstruction. In Conf Proc IEEE Eng Med Biol Soc, Lyon, France, September 2007.


  111. [RIT-07c] S. Rit, D. Sarrut, and S. Miguet. Gated cone-beam CT imaging of the thorax: a reconstruction study. In SPIE Medical Imaging, San Diego, California, USA, February 2007.


  112. [ROBI-07a] M. Robini and I.E. Magnin. Stochastic Continuation. Opening new horizons to solving difficult optimization problems. In Proc. 14th IEEE Workshop on Statistical Signal Processing, Madison, Wisconsin, pages 264-268, 2007.


  113. [ROSE-07] J.L. Rose, C. Revol-Muller, M. Almajdub, E. Chereul, and C. Odet. Shape Prior Integrated in an Automated 3D Region Growing method. In IEEE International Conference on Image Processing ICIP'07, San Antonio, USA, pages 53-56, September 2007.


  114. [ROUC-07a] Y. Rouchdy, J. Pousin, J. Schaerer, and P. Clarysse. A hyperelastic deformable template for cardiac segmentation in MRI. In Functional Imaging and Modeling of the Heart, volume LNCS 4466, Salt Lake City, UT, USA, pages 443-452, June 2007.


  115. [SCHA-07b] J. Schaerer, P. Clarysse, and J. Pousin. A New Dynamic Elastic Model for Cardiac Image Analysis. In Proceedings of the 29th Annual International Conference of the IEEE EMBS, Lyon, France, pages 4488-4491, August 2007.


  116. [SCHA-07a] J. Schaerer, A. Gelas, R. Prost, P. Clarysse, and I. E. Magnin. Volumetric Mesh Construction From Scattered Prior Data: Application To Cardiac MR Image Analysis. In European Signal Processing Conference, Poznan, Poland, pages 438-442, September 2007.


  117. [STUP-07] V. Stupar, A. Al Faraj, H. Alsaid, E. Bannier, K. Cieslar, S. Gaillard, E. Canet-Soulas, and Y. Crémillieux. Hyperpolarized 3He MRI: a comprehensive tool for the investigation of lung function in physio-pathological animal models. In Contrast Media Research - CMR, Banff, Canada, 2007.


  118. [TOME-07b] S. Tomei, C. Odet, and C. Lartizien. Détection d'hyper signaux en Tomographie par Emission de Positons 3D : Approche statistique basée sur la combinaison d'une transformée en ondelettes discrète avec un test de Hotelling. In Colloque GRETSI, Troyes, France, pages 869-872, 2007.


  119. [VALT-07c] S. Valton, P. Bérard, J. Riendeau, C. Thibaudeau, R. Lecomte, D. Sappey-Marinier, and F. Peyrin. Comparison of analytical and algebraic 2D tomographic reconstruction approaches for irregularly sampled microCT data. In IEEE EMBC 2007, Lyon, France, pages 2916-2919, 2007.


  120. [VALT-07b] S. Valton, P. Bérard, J. Riendeau, C. Thibaudeau, R. Lecomte, D. Sappey-Marinier, and F. Peyrin. Fan Beam Reconstruction for Non-standard Equiangular Detector with a FBP Formula. In International Meeting on Fully Three-dimensional Image Reconstruction in Radiology and Nuclear Science, Lindau, Germany, pages 225-228, 2007.


  121. [VAND-07] J. Vandemeulebroucke, D. Sarrut, and P. Clarysse. Point-validated Pixel-based Breathing Thorax Model. In International Conference on the Use of Computers in Radiation Therapy (ICCR), Toronto, Canada, June 2007.


  122. [WANG-07] X. Wang, J. Schaerer, Z. Qian, D. Metaxas, T. Chen, and L. Axel. Reconstruction of Detailed Left Ventricle Motion Using Deformable Model from Tagged MR Image. In Functional Imaging and Modeling of the Heart, pages 60-68, 2007.


  123. [WU-07] Z. Wu, G. Sharp, E. Rietzel, V. Boldea, and D. Sarrut. Validation of deformable registration of lung 4DCT with anatomical sub-region segmentations. In International Conference on the Use of Computers in Radiation Therapy (ICCR), Toronto, Canada, June 2007.


  124. [YANK-07a] J. Yankam-Njiwa, B. Hiba, and Y.M. Zhu. Cardiac Cine MR Reconstruction From Partial k-Space Using the Notion of Analytic Image. In Conf Proc IEEE Eng Med Biol Soc, volume 2007, Lyon, France, pages 2057-2060, August 2007.


  125. [ZAHR-07] N. Zahra, P. Lautesse, L. Guigues, T. Frisson, and D. Sarrut. Geant4-based simulation of Carbon beam irradiation inside CT image : validation with radiochromic films. In 11th HCBPM (Heavy Charged Particles in Biology & Medicine) IBIBAM (Ion Beams In Biology and Medicine), Heidelberg, September 2007.


  126. [ZULU-07a] M.A. Zuluaga, E.E. Davila-Serrano, L.F Uriza, and M. Hernandez Hoyos. Carotid artery segmentation and characterization in 3D computed tomography (CT) images. In 21st CARS - Comput Assisted Radiol Surg, volume 2, Berlin, Germany, pages S72 - S74, June 2007.


Invited Conferences
  1. [COUR-07b] G. Courbebaisse. Lattice Boltzmann flows. In Workshop COST P19, Summer school, Lappeenranta, Finland, June 2007.


  2. [COUR-07a] G. Courbebaisse. Lattice Boltzmann method and simulation of complex physical phenomena. In CCP2007 - COST P19, CONFERENCE on Computational Physics, Brussels, Belgium, September 2007.


  3. [GRAV-07] D. Graveron-Demilly. Magnetic Resonance Spectroscopic Imaging, Toward Non-Invasive In Vivo Assessment of Metabolic Content. In ProRISC 2007, Veldhoven, The Netherlands, November 2007.


  4. [JIAO-07] S.H. Jiao and R. Goutte. Stéganocryptographie en imagerie médicale. In 4e Conférence internationale SETIT, Hammamet, Tunisie, 2007.


  5. [MAGN-07] I.E. Magnin. Cardiac imaging. In XII International Congress for Stereology (ICS XII'07), Saint Etienne, France, September 2007.


  6. [PEYR-07f] F. Peyrin. Analyse 3D de la micro-architecture osseuse par imagerie tomographique synchrotron. In , Université Paris 5, Paris, Paris, 2007.


  7. [PEYR-07e] F. Peyrin. Analyse de l'os cortical par imagerie micro-tomographique. In Séminaire Qualité osseuse, Servier, Paris, 2007.


  8. [WIAR-07] M. Wiart, N. Davoust, J.B. Pialat, N. Nighoghossian, and Y. Berthezène. Magnetic resonance imaging (MRI) of inflammation in stroke. In Conf Proc IEEE Eng Med Biol Soc, volume 1, Lyon, France, pages 4316-4319, 2007.


Miscellaneous
  1. [BEUF-07] O. Beuf, F. Pilleul, H. Saint-Jalmes, F. Jaillon, M. Armenean, J-F. Piranda, S. Delforge, and E. Mahler. Brevet N. 0759652 - Français. Extension PCT/FR2008/052248. Sonde endocavitaire pour l'imagerie et/ou la spectrométrie par résonance magnétique nucléaire, 2007.


  2. [BRUS-07c] E. Brusseau, J.F. Deprez, F. Duboeuf, and O. Basset. 2D Locally regularized deformation imaging during freehand examination: initial results. 6th International Conference of the Ultrasonic Measurement and Imaging of Tissue Elasticity, november 2007.


  3. [BUCU-07] A. Bucur, A. Bernard, C. Cudalbu, P. Giraudon, D. Graveron-Demilly, H. Ratiney, and S. Cavassila. Analyse quantitative des altérations du métabolisme dans un modèle animal de neuro-inflammation viro-induit par spectrométrie de résonance magnétique. Rencontres Scientifiques de l'Institut Fédératif des Neurosciences de Lyon, December 2007.


  4. [BUCU-07b] A. Bucur, A. Bernard, C. Cudalbu, P. Giraudon, D. Graveron-Demilly, H. Ratiney, and S. Cavassila. Analyse quantitative des altérations du métabolisme dans un modèle animal de neuro-inflammation viro-induit par spectrométrie de résonance magnétique. Réunion scientifique de l'Institut Fédératif de Recherche-62 Lyon Est, Faculté de médecine Laennec, December 2007.


  5. [FAKR-07] L. Fakri-Bouchet, N. Baxan, A. Rengle, H. Rabeson, G. Pasquet, J.-F. Châteaux, A. Briguet, P. Morin, and D. Graveron-Demilly. Micro Spectroscopie RMN: Limite de détection de métabolites cérébraux ( 100 nL). Proc CNRIUT, 2007.


  6. [GREN-07f] D. Grenier. Brevet N. 0757654 - Français. PCT N. EP2008/062480. Acquisition de signaux dans un espace hypercomplexe, 2007.


  7. [LING-07] Diane Lingrand, Tristan Glatard, and Johan Montagnat. Taking into account the execution context to optimize medical image databases indexation. Second Singaporean-French Biomedical Imaging Workshop (SFBI'07), August 2007.



BACK TO INDEX




Disclaimer:

This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All person copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Les documents contenus dans ces répertoires sont rendus disponibles par les auteurs qui y ont contribué en vue d'assurer la diffusion à temps de travaux savants et techniques sur une base non-commerciale. Les droits de copie et autres droits sont gardés par les auteurs et par les détenteurs du copyright, en dépit du fait qu'ils présentent ici leurs travaux sous forme électronique. Les personnes copiant ces informations doivent adhérer aux termes et contraintes couverts par le copyright de chaque auteur. Ces travaux ne peuvent pas être rendus disponibles ailleurs sans la permission explicite du détenteur du copyright.




Last modified: Wed Oct 20 17:12:38 2010
Author: mail.


This document was translated from BibTEX by bibtex2html